Module Description
The module is in the following construction step:
Setup

No optical readout is used, we use the electrical lines.


Parameters

Noise Scan
A trimming was done at Qin=0.0fC (Noise Scan), using the 60mV range. The Threshold value that minimizes the spread was 52.5 mV. Using this trimming, a Noise Scan was done and instability was observed.
Common Mode
Using the trimming at 0fC and setting the threshold at 0fC, 20.000 events were analyzed. Multiplicity.eps shows the number of hits per event (over 1) and the spread of this distribution, for both, top and bottom planes. The calculated Gamma gives 38% of Common Mode on top plane and 9% of Common Mode on bottom plane.

Plotting the Correlation Matrix (Correlation.jpg) one can observe a very low correlation (0.002) for channels of different chip (if both chips are not on the top plane), a bit more (0.031) for channels within the same chip on the bottom plane. For channels on the top plane the correlation is bigger (0.09) (correlaciones.ps). Among the channels of this last group, channels at the border of the chips have bigger correlation to the others.


Trimming
The trimming was done at Qin=1.0fC, using the 60mV range. The Threshold value that minimizes the spread at 1.0fC is 92.5 mV.
Bad channels

Calibration

Chip M0S1S2 S3S4E5Front
Gain(mV/fC) 51.953.353.353.954.852.653.3
ENC(@2fC)(e-)11751163 12031250108511621173
Chip M8S9S10 S11S12E13Back
Gain(mV/fC) 50.746.850.652.051.150.450.3
ENC(@2fC)(e-)868 706 709 653 742 696 729

Plots:

The observed excess noise on the bottom plane respect to the hybrid measurement could be due to the bonding to the fanins, incrementing the interchannel capacity.